PY60-A
CHT GAUGE
The PY60-A works with both J and K type thermocouples to provide accurate monitoring of engine cylinder head or exhaust gas temperatures from -4 to 2012 F (-20 to 100 C).  HIGH and LOW temperature alarms can be set from 32-2012 F (0-1100 C).  When activated, the built-in 85dB alarm sounds, and the display will flash.  The highest temperature seen is automatically saved to a non-volatile memory and can be displayed/reset at any time.  Five levels of backlighting can be selected and all setup and calibration constants are saved to a non-volatile memory.




PY60-A
CHT Gauge
219.95




AD-2000TK
Type K Thermocouple


PY60-A   CHT Specifications

Power Supply: 
                   9.5 - 33.0 VDC, (.018 amp nominal)

Operating Temp:               32 - 122F (0-50C)

Size/ Weight:                      2.475” square bezel, with standard aviation 2.250” raised round ring.
                                              Standard 2.625” diameter mounting hole layout at 45 degrees.  Unique
                                              bezel design allows user either front or rear mounting in your panel. 
                                              Gauge depth behind panel: surface mounted approx 2.60”, rear mounted,
                                              approx. 2.90”.  Weight approx 2.3 oz.

Thermocouple:                  Type J or K

Measurement Range:     -4 - 2012 F (-20-1100 C)

Accuracy:                          Better than +/- 1%, front panel adjustable calibration

Alarms:                              HIGH and LOW temperature settable from 32-2012 F (0-1100 C)    

Display:                              4 digit, Fahrenheit or Celsius.  Five levels of backlighting.

Output:                               Terminal B can be selected and used as an External Alarm output if
                                             desired.  For an CHT high temp warning indicator light.